The Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring both the level and velocity of flowing liquid to calculate flow measurement in an open channel or pipe. The sensors are mounted either inside a pipe or at the bottom of a channel, and the sensor is built to resist fouling, corrosion, and abrasion. The AVFM 6.1 Area Velocity Flow Meter can be configured with the standard submerged velocity-level sensor or with submerged velocity in combination with a separate non-contacting ultrasonic level sensor, which is suitable for highly aerated fluids or those with a high concentration of suspended solids.
The AVFM 6.1 can measure forward flow velocity up to 6 m/s (19.7 ft/s) and reverse flow up to 1.5 m/s (5 ft/s). The electronics and software sample and average flow rates continuously provide stable readings. The submerged velocity/level sensor will measure flow in partially full and surcharged pipes with pressure up to 10 psi. The minimum recommended pipe diameter for the AVFM 6.1 Area-Velocity Flow Meter is 150 mm (5.9 in).
Configuration is simple for the AVFM 6.1 Area Velocity Flow Meter. Just enter the pipe diameter or channel dimensions and the AVFM 6.1 automatically computes and displays flow volume. Configure the AVFM 6.1 for installation in irregular or compound channel shapes by entering the channel width and multiple level points through the simple menu system. Channels for virtually any shape can be monitored with your choice of measurement units.
The Flow Meter will store time and date-stamped flow values at 10-second to 6-minute intervals. Daily flow reports are automatically created where total, minimum, maximum, and average flow rates are displayed on the LCD display. Transfer log files and daily flow reports to any USB flash drive by connecting to the logger’s USB output.
The AVFM 6.1 Area Velocity Flow Meter is suitable for open channel measurement applications such as influent flow monitoring, effluent flow monitoring, wastewater, stormwater, industrial wastewater applications, and irrigation water flow measurement. Its easy-to-use, menu-driven setup means that the AVFM 6.1 Area-Velocity Flow Meter is just minutes away from giving you that all-important flow measurement result.
Skip to the end of the images gallery
Skip to the beginning of the images gallery
- No flume or weir required – submersible ultrasonic sensor measures velocity and level simultaneously to calculate flow. No moving parts to wear, foul, or clog.
- The built-in 5-button keypad, intuitive menu, and large backlit LCD display make the AVFM 6.1 the most operator-friendly area-velocity flow meter on the market.
- Fast, simple, installation and set-up.
- Improved performance in a wider range of operating conditions.
- At a glance, view flow rate, velocity, level, totalizer, relay status, and important diagnostic information on the LCD display.
- Three isolated 4-20 mA outputs for flow rate, velocity, and level, and two relay outputs for pulse output or alarm.
- 6.5 million point data logger for greater flexibility of data monitoring, control, and reporting.
- Min, Max, and Total Flow data from the last 365 days is available on the LCD display, or download directly to a USB for easy reporting.
- Monitors flow rate, volume total, run hours, and diagnostic information through only two wires with the optional Modbus RTU serial communication output.
General Specifications | |
---|---|
Spec name: | Description: |
Channel Types | Round pipe, rectangular, trapezoid, egg, or custom shapes |
Electronics Enclosure | NEMA4X (IP 66) polycarbonate with clear, shatterproof cover |
Accuracy | Level: ±0.25% of reading or ±0.08 in, whichever is greater. Repeatability & Linearity 0.1%. Velocity: ±2% of reading or ±0.012 m/s (0.04 ft/s), whichever is greater. Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability & Linearity 0.5% |
Display | White, back-lit matrix - displays flow rate, totalizer, relay states, operating mode, and calibration menu |
Programming | Built-in 5-key calibrator with English, French, or Spanish language selection |
Power Input | 100-240 V AC 50/60 Hz, 10 VA maximum. Optional: 9-32 V DC, 10 W maximum |
Outputs | 3 Isolated 4-20 mA, 1000 ohm, (Flow, Level, and Velocity) or 0-5 V DC by menu selection |
Control Relays | 2 Relays, form 'C' dry contacts rated 5 amp SPDT; programmable for flow proportional pulse (sampler/totalizer), flow, and/or level alarm |
Data Logging | Programmable 26 million point data capacity, time and date stamped plus formatted flow reports including Total, Average, Minimum, Maximum, and times of occurrence. Includes USB output to Flash Drives and Windows software |
Operating Temperature(Electronics): | -20 °C to 60 °C (-5 °F to 140 °F) |
Approximate Shipping Weight | 4.5 kg (10 lbs) |
QZ02L Sensor Specifications | |
---|---|
Spec name: | Description: |
Velocity Measurement Range | 0.031 m/s to 6.2 m/s (0.1 ft/s to 20 ft/s) and reverse flow to -1.5 m/s (-5 ft/s) in fluids containing bubbles or solids with a minimum size of 100 microns and a minimum concentration of 75 ppm to act as acoustic reflectors |
Level Measurement Range | Minimum Head: 25.4 mm (1 in). Maximum Head: 4.57 m (15 ft) |
Operating Temperature | -15 °C to 80 °C (5 °F to 175 °F) |
Exposed Materials | 316 stainless steel, epoxy resin, polyurethane |
Sensor Cable | 7.6 m (25 ft) submersible polyurethane jacket, shielded, 3-coaxial |
Sensor Mounting | Includes MB-QZ stainless steel mounting bracket |
Temperature Compensation | Automatic, continuous |
Options | |
---|---|
Options: | Description: |
Industrial Automation Protocols | Modbus RTU via RS-485 |
Sensor Cable | 15 m (50 ft) or 30 m (100 ft) submersible, continuous from Sensor - or splice up to a total of 150 m (500 ft) length |
Sensor Cable Junction Box | NEMA4 polycarbonate with connection terminal strip |
Enclosure Heater | Thermostatically controlled to -40 °C (-40 °F); recommended for temperatures below 0 °C (32 °F) |
Intrinsic Safety Barriers | For Sensor mounting in Class I,II,III, Div. I,II, Groups C,D,E,F,G hazardous locations |
Sensors | Separate non-contacting ultrasonic level sensor and submerged velocity sensor |
Sensor Mounting Bands | Stainless steel sensor mounting bands for pipes 150 mm to 1800 mm (6 in to 72 in) diameter |
AVFM 6.1
Product Brochure
Download
AVFM 6.1
Datasheet
Download
AVFM 6.1
Order Form
Download
AVFM 6.1
Installation & Instruction Manual
Download
AVFM 6.1
Engineering Specifications
Download
Greyline Logger
Software
Download
Greyline Logger
Software Brochure
Download
Greyline Electrical Safety
North America Electrical Safety Certificate
Download
PZ Sensor Haz Loc
North America Haz Loc Certificate
Download
QZ Sensor Haz Loc
North America Haz Loc Certificate
Download
SE Sensor
North America Haz Loc Certificate
Download
AVFM 6.1
CE Declaration of Conformity
Download
VSJ Half-Pipe Mounting Bands
Datasheet
Download
VSJ Pipe Mounting Band
Datasheet
Download
Explosion Proof Enclosure
Datasheet
Download
Greyline Enclosure Panel Mount
Datasheet
Download
JB2X Sensor Cable Junction Box
Datasheet
Download
SCR Enclosure Sun Screen
Datasheet
Download
SP4 Surge Protection
Datasheet
Download
AVFM 6.1
Case Study | Wastewater flow monitoring
Download
AVFM 6.1
Case Study | AVFM 6.1 Outlet Pipe Monitoring
Download
AVFM 6.1
Case Study | Open Channel Flow Measurement for Phu My 3 Industrial Wastewater Treatment Plant.
Download
AVFM 6.1
Case Study | AVFM 6.1 provides open channel flow monitoring for cooling water.
Download
AVFM 6.1
Case Study | AVFM 6.1 Provides Discharge Monitoring for Steel Factory in Thailand.
Download
AVFM 6.1
Case Study | Irrigation water flow measurement.
Download
AVFM 6.1
Case Study | Non-contacting flow solution for heap leach mining.
Download
AVFM 6.1
Case Study | Quarry dewatering with AVFM 6.1
Download
AVFM 6.1
Case Study | AVFM 6.1 provides area velocity readings for textile industry in Viet Nam
Download
Warranty
Pulsar Measurement Product Warranty
Download
- CE
- CSA
- UL
- EN 61010-1
Related Products
-
MantaRay
View Details -
Stingray 2.0
View Details -
OCF 6.1
View Details -
FlowCERT
View Details -
MicroFlow
View Details