AVFM 6.1 Area Velocity Flow Meter| Pulsar Measurement (2024)

The Area Velocity Flow Measurement method is the most common method of all flow measurements. The AVFM 6.1 Area Velocity Flow Meter uses a submersible ultrasonic sensor measuring both the level and velocity of flowing liquid to calculate flow measurement in an open channel or pipe. The sensors are mounted either inside a pipe or at the bottom of a channel, and the sensor is built to resist fouling, corrosion, and abrasion. The AVFM 6.1 Area Velocity Flow Meter can be configured with the standard submerged velocity-level sensor or with submerged velocity in combination with a separate non-contacting ultrasonic level sensor, which is suitable for highly aerated fluids or those with a high concentration of suspended solids.

The AVFM 6.1 can measure forward flow velocity up to 6 m/s (19.7 ft/s) and reverse flow up to 1.5 m/s (5 ft/s). The electronics and software sample and average flow rates continuously provide stable readings. The submerged velocity/level sensor will measure flow in partially full and surcharged pipes with pressure up to 10 psi. The minimum recommended pipe diameter for the AVFM 6.1 Area-Velocity Flow Meter is 150 mm (5.9 in).

Configuration is simple for the AVFM 6.1 Area Velocity Flow Meter. Just enter the pipe diameter or channel dimensions and the AVFM 6.1 automatically computes and displays flow volume. Configure the AVFM 6.1 for installation in irregular or compound channel shapes by entering the channel width and multiple level points through the simple menu system. Channels for virtually any shape can be monitored with your choice of measurement units.

The Flow Meter will store time and date-stamped flow values at 10-second to 6-minute intervals. Daily flow reports are automatically created where total, minimum, maximum, and average flow rates are displayed on the LCD display. Transfer log files and daily flow reports to any USB flash drive by connecting to the logger’s USB output.

The AVFM 6.1 Area Velocity Flow Meter is suitable for open channel measurement applications such as influent flow monitoring, effluent flow monitoring, wastewater, stormwater, industrial wastewater applications, and irrigation water flow measurement. Its easy-to-use, menu-driven setup means that the AVFM 6.1 Area-Velocity Flow Meter is just minutes away from giving you that all-important flow measurement result.

Skip to the end of the images gallery

AVFM 6.1 Area Velocity Flow Meter| Pulsar Measurement (1)

Skip to the beginning of the images gallery

  • No flume or weir required – submersible ultrasonic sensor measures velocity and level simultaneously to calculate flow. No moving parts to wear, foul, or clog.
  • The built-in 5-button keypad, intuitive menu, and large backlit LCD display make the AVFM 6.1 the most operator-friendly area-velocity flow meter on the market.
  • Fast, simple, installation and set-up.
  • Improved performance in a wider range of operating conditions.
  • At a glance, view flow rate, velocity, level, totalizer, relay status, and important diagnostic information on the LCD display.
  • Three isolated 4-20 mA outputs for flow rate, velocity, and level, and two relay outputs for pulse output or alarm.
  • 6.5 million point data logger for greater flexibility of data monitoring, control, and reporting.
  • Min, Max, and Total Flow data from the last 365 days is available on the LCD display, or download directly to a USB for easy reporting.
  • Monitors flow rate, volume total, run hours, and diagnostic information through only two wires with the optional Modbus RTU serial communication output.
General Specifications
Spec name:Description:
Channel TypesRound pipe, rectangular, trapezoid, egg, or custom shapes
Electronics EnclosureNEMA4X (IP 66) polycarbonate with clear, shatterproof cover
AccuracyLevel: ±0.25% of reading or ±0.08 in, whichever is greater. Repeatability & Linearity 0.1%.
Velocity: ±2% of reading or ±0.012 m/s (0.04 ft/s), whichever is greater. Requires solids or bubbles minimum size of 100 microns, minimum concentration 75 ppm. Repeatability & Linearity 0.5%
DisplayWhite, back-lit matrix - displays flow rate, totalizer, relay states, operating mode, and calibration menu
ProgrammingBuilt-in 5-key calibrator with English, French, or Spanish language selection
Power Input100-240 V AC 50/60 Hz, 10 VA maximum.
Optional: 9-32 V DC, 10 W maximum
Outputs3 Isolated 4-20 mA, 1000 ohm, (Flow, Level, and Velocity) or 0-5 V DC by menu selection
Control Relays2 Relays, form 'C' dry contacts rated 5 amp SPDT; programmable for flow proportional pulse (sampler/totalizer), flow, and/or level alarm
Data LoggingProgrammable 26 million point data capacity, time and date stamped plus formatted flow reports including Total, Average, Minimum, Maximum, and times of occurrence. Includes USB output to Flash Drives and Windows software
Operating Temperature(Electronics):-20 °C to 60 °C (-5 °F to 140 °F)
Approximate Shipping Weight4.5 kg (10 lbs)

QZ02L Sensor Specifications
Spec name:Description:
Velocity Measurement Range0.031 m/s to 6.2 m/s (0.1 ft/s to 20 ft/s) and reverse flow to -1.5 m/s (-5 ft/s) in fluids containing bubbles or solids with a minimum size of 100 microns and a minimum concentration of 75 ppm to act as acoustic reflectors
Level Measurement RangeMinimum Head: 25.4 mm (1 in). Maximum Head: 4.57 m (15 ft)
Operating Temperature-15 °C to 80 °C (5 °F to 175 °F)
Exposed Materials316 stainless steel, epoxy resin, polyurethane
Sensor Cable7.6 m (25 ft) submersible polyurethane jacket, shielded, 3-coaxial
Sensor MountingIncludes MB-QZ stainless steel mounting bracket
Temperature CompensationAutomatic, continuous
Options
Options:Description:
Industrial Automation ProtocolsModbus RTU via RS-485
Sensor Cable15 m (50 ft) or 30 m (100 ft) submersible, continuous from Sensor - or splice up to a total of 150 m (500 ft) length
Sensor Cable Junction BoxNEMA4 polycarbonate with connection terminal strip
Enclosure HeaterThermostatically controlled to -40 °C (-40 °F); recommended for temperatures below 0 °C (32 °F)
Intrinsic Safety BarriersFor Sensor mounting in Class I,II,III, Div. I,II, Groups C,D,E,F,G hazardous locations
SensorsSeparate non-contacting ultrasonic level sensor and submerged velocity sensor
Sensor Mounting BandsStainless steel sensor mounting bands for pipes 150 mm to 1800 mm (6 in to 72 in) diameter

AVFM 6.1

Product Brochure

Download

AVFM 6.1

Datasheet

Download

AVFM 6.1

Order Form

Download

AVFM 6.1

Installation & Instruction Manual

Download

AVFM 6.1

Engineering Specifications

Download

Greyline Logger

Software

Download

Greyline Logger

Software Brochure

Download

Greyline Electrical Safety

North America Electrical Safety Certificate

Download

PZ Sensor Haz Loc

North America Haz Loc Certificate

Download

QZ Sensor Haz Loc

North America Haz Loc Certificate

Download

SE Sensor

North America Haz Loc Certificate

Download

AVFM 6.1

CE Declaration of Conformity

Download

VSJ Half-Pipe Mounting Bands

Datasheet

Download

VSJ Pipe Mounting Band

Datasheet

Download

Explosion Proof Enclosure

Datasheet

Download

Greyline Enclosure Panel Mount

Datasheet

Download

JB2X Sensor Cable Junction Box

Datasheet

Download

SCR Enclosure Sun Screen

Datasheet

Download

SP4 Surge Protection

Datasheet

Download

AVFM 6.1

Case Study | Wastewater flow monitoring

Download

AVFM 6.1

Case Study | AVFM 6.1 Outlet Pipe Monitoring

Download

AVFM 6.1

Case Study | AVFM 6.1 provides flow measurement for a prawn farming project.

Download

AVFM 6.1

Case Study | Open Channel Flow Measurement for Phu My 3 Industrial Wastewater Treatment Plant.

Download

AVFM 6.1

Case Study | AVFM 6.1 provides open channel flow monitoring for cooling water.

Download

AVFM 6.1

Case Study | AVFM 6.1 Provides Discharge Monitoring for Steel Factory in Thailand.

Download

AVFM 6.1

Case Study | Irrigation water flow measurement.

Download

AVFM 6.1

Case Study | Non-contacting flow solution for heap leach mining.

Download

AVFM 6.1

Case Study | Quarry dewatering with AVFM 6.1

Download

AVFM 6.1

Case Study | AVFM 6.1 provides area velocity readings for textile industry in Viet Nam

Download

Warranty

Pulsar Measurement Product Warranty

Download

  • CE
  • CSA
  • UL
  • EN 61010-1

Related Products

  • MantaRay

    View Details
  • Stingray 2.0

    View Details
  • OCF 6.1

    View Details
  • FlowCERT

    View Details
  • MicroFlow

    View Details
AVFM 6.1 Area Velocity Flow Meter| Pulsar Measurement (2024)
Top Articles
Latest Posts
Article information

Author: Errol Quitzon

Last Updated:

Views: 5667

Rating: 4.9 / 5 (59 voted)

Reviews: 90% of readers found this page helpful

Author information

Name: Errol Quitzon

Birthday: 1993-04-02

Address: 70604 Haley Lane, Port Weldonside, TN 99233-0942

Phone: +9665282866296

Job: Product Retail Agent

Hobby: Computer programming, Horseback riding, Hooping, Dance, Ice skating, Backpacking, Rafting

Introduction: My name is Errol Quitzon, I am a fair, cute, fancy, clean, attractive, sparkling, kind person who loves writing and wants to share my knowledge and understanding with you.